Manual Mode

Manual Mode is used for "on-the-fly" operations where you need to move fluid without running a pre-set Work Order. Think of it as running an automated input without a Work Order: it uses the system's intelligent sequencing to operate inputs, but you decide when to start and stop the flow.

[!WARNING]

No Failsafes: Manual Mode does not provide any automated stops or safety overrides. You are in full control of all hardware.

No Record Keeping: Unlike the Mix tab, actions taken in this specific mode do not generate a data record or update chemical inventory. Neither Manual Mode nor Diagnostics Mode creates a Work Record — anything moved here is "off the books."


The screen is organized by Input Cards, one per configured product or carrier input.

  • Automatic Sequencing: When you press Start on an input card, the system automatically sequences the flowmeter and all appropriate valves to make that specific input work — you don't have to open each valve individually.

  • User Control: The flow continues until you press Done on that card, which tells the system to close all associated valves.

  • Inductor Behavior: The Jug Rinse and Continuous Flow functions work exactly the same way they do during a standard mix. When you press Done on an Inductor card, the system automatically drains the inductor to the set level before finishing.


  • Priming and Flushing: The standard tool for filling lines with carrier water or flushing out the manifold and hoses at the end of a field.

  • Manual Transfers: When you simply need to move a volume of fluid from one point to another.

  • Quick Testing of Operations: Allows you to verify that a pump is spinning or a valve is turning without having to build a Work Order first.


Before navigating away from the Manual Mode tab, always ensure:

All Cards are White and show the Start buttom on them.