System Level Errors
101 - Unexpected Flow - Detects flow through a non used measurement device - If you see this, a valve is not closing properly.
102 - Failed SRAM - Master Controller memory chip failure, call your dealer to get a new one coming.
103 - Emergency Stop Request from Machine - Something caused emergency stop to be enacted from the machine side,
See Blink Codes104 - Supply Voltage is low and needs attention - The power getting supplied to the Mixmate is low enough that is not enacting emergency shut-down, but you need to get a charger on your battery.
Mixmate Wiring105 - Critical Device Missing - Whatever module the error says, the Mixmate did not find it during boot up. Check cables and reboot the Mixmate to try again.
Operation Level Errors
201 - No Flow Error - Measurement device is not seeing flow when it is expecting to see flow - Is the valve opening? Is there a filter plugged? Are pumps running?
202 - Check Inductor Emtpy - Inductor is not reaching expected Drain Weight - Is the drain valve opening? Are pumps running? Are valves open?
Reset Drain Weight203 - Flow Not Stopping - Measurement device is seeing flow even after attempting to close valves - Are valves closing?
204 - Device Missing - Whatever device the error says, the Mixmate did not find it during boot up. Check cables and reboot the Mixmate to try again.
208 - Failed CAN Message - Machine throws this when a module is not reporting back to the Master Controller reliably. This should come with a 3 blink error code on the Power Module.
Check cables and reboot the Mixmate to try again. CAN Bus Diagnostics | Power Diagnostics
Connection Errors
301 - Failed Device Message - This message states the tablet attempted to send a message to the machine and the machine was unable to process the request. Most common reason for this error is due to a mismatch of configuration in the tablet and what the machine is seeing for devices on the CAN bus. Kill app, reboot Mixmate and try again. This error will typicallly be followed by a 302 and 401 error.
302 - Failed Device Communications - Communications between Tablet and Machine failed to be established. Kill app, reboot Mixmate and try again.
Internal Errors
Unknown Errors