System Level Errors
101 - Unexpected Flow - Detects flow through a non used measurement device
102 - Failed SRAM - Master Controller memory chip failure, need new module
103 - Emergency Stop Request from Machine - Something caused emergency stop to be enacted from the machine side,
See Blink Codes104 - Supply Voltage is low and needs attention
105 - Critical Device Missing - Tablet is requesting usage of a module that is not currently available on the machine
Operation Level Errors
201 - No Flow Error - Measurement device is not seeing flow when it is expecting to see flow
202 - Check Inductor Emtpy - Inductor is not reaching expected Drain Weight
203 - Flow Not Stopping - Measurement device is seeing flow even after attempting to close valves
204 - Device Missing - Tablet is requesting usage of a module that is not currently available on the machine
205 - Manual Inductor Empty - Pops this to pause operation to allow User to Empty the Inductor (For Use with Custom Inductors built by Customers)
206 - Manual Inductor Rinse - Pops this to pause operation to allow User to Rinse the Inductor or Jugs (For Use with Custom Inductors built by Customers)
207 - Manual Inductor Prefill - Pops this to pause operation to allow User to Prefill the Inductor (For Use with Custom Inductors built by Customers)
208 - Failed CAN Message - Machine throws this when a module is not responding as expected
Connection Errors
301 - Failed Device Message - This message states the tablet attempted to send a message to the machine and the machine was unable to process the request
302 - Failed Device Communications - Communications between Tablet and Machine failed to be established
Internal Errors
401 - Connection Lost - Communications between Tablet and Machine have unexpectedly quit