Mixmate power diagnostics
- Check battery voltage - minimum should be 12.3 volts
- Check screws on back of battery disconnect switch
- Check fuses
- Pro Inductor: 15 amp (x2) in fuse panel (black box, rear top of unit)
- Fusion Inductor: Auto-resetting circuit breakers
- External Starter: in-line fuse, inside housing
- Check voltage entering Power Module
- Remove cover to white box
- Wires are labeled on circuit board
- 12 volt IN should match battery voltage
- Out (1 and 2) should match battery voltage with battery disconnect switch ON position
- Power indicators to check
- Stack valve lights on
- Internal valves in Inductors light up
*** Make sure all pins are fully seated and pins well crimped.