Mixmate power diagnostics

Mixmate power diagnostics

  1. Check battery voltage - minimum should be 12.3 volts
  2. Check screws on back of battery disconnect switch
  3. Check fuses
    1. Pro Inductor: 15 amp (x2) in fuse panel (black box, rear top of unit)
    2. Fusion Inductor: Auto-resetting circuit breakers
    3. External Starter: in-line fuse, inside housing
  4. Check voltage entering Power Module
    1. Remove cover to white box
    2. Wires are labeled on circuit board
    3. 12 volt IN should match battery voltage
    4. Out (1 and 2) should match battery voltage with battery disconnect switch ON position
  5. Power indicators to check
    1. Stack valve lights on
    2. Internal valves in Inductors light up
*** Make sure all pins are fully seated and pins well crimped.