Power Module Blink Code Diagnostics
The power module now has blink codes. The number of flashes happens once every 5 seconds. The power must be cycled to clear the code.
1 blink - Low Voltage Dropout ( resets below approximately 11 volts ), get a charger on your battery! - Reboot Mixmate and try again -
Further Details2 blinks - Master Controller unexpected error. - Reboot Mixmate and try again.
3 blinks - CAN bus error while running operations - Reboot Mixmate and try again.
4 blinks - Tablet Communications Lost while running operations - Mixmate was in the middle of measuring operations and stopped receiving communications from the tablet, so the Mixmate applied a emergency stop. The Mixmate automatically resets communications on its side and waits for the tablet to reestablish communications. Either try going back into manual mode or restarting the Mix.