Mixmate (Machine Configuration)
Mixmates
Manual Mode: Use the at the right side of the line to open the modal and then click on manual mode. Editing a Mixmate: Do NOT enter if you do not know what you are doing as it may break your machine. Tap on the center of the bar containing Mixmate ...
How do I adjust the inductor calibration?
There is an existing article found here: https://support.praxidyn.com/portal/en/kb/articles/calibration-of-inductors
How do I adjust a flowmeter calibration?
For gear meters or mass-flow meters, there are no adjustments as these are factory calibrated. For paddle meters or mag meters, there will be individual calibrations in configuration settings. For example. go to the Data tab > Mixmates > tap in the ...
What is Scale Reaction Speed?
Scale reaction speed refers to how sensitive the scale is to vibrations (e.g., pumps, etc.). To adjust this, go to Data tab > Mixmates > tap in the middle of the Mixmate select (around where it lists the Master Module) > tap Proceed > Assemblies > ...
How do I add valves, flowmeters, etc.. to my configuration?
If you'd like to add or remove items from your Mixmate system, please contact your dealer or contact Praxidyn support directly.
How does partial valve position work? What does auto do?
Partial valve position is the feature by which the user can adjust the valve positioning of the carrier/main valve to increase or restrict the flow of water and thus allowing the increase or restriction of product flow. For example, by closing the ...
How does holdback work?
"Holdback" is a function by which the main/carrier valve closes to allow for maximum suction on chemical/product induction. By closing off the carrier (temporarily) all available suction can be dedicated to introducing product(s) to your blend tank ...
Flowmeter Calibration
The carrier meters that are used with the system typically have to be calibrated after final installation because they are sensitve to how the liquid flows through them. We typically like to see how the total comes out over a period of 3 loads before ...
What is Holdback?
Minimum Holdback - Default is 50 Gallons Partial Valve Position - Partial Valve Position is how far open the carrier valve is while adding products. The more open the carrier valve, the slower the product will flow, and the faster holdback will be ...
Mag meter not measuring properly
Are power, signal lights lit? Check connection, cabling, plugs are seated securely. Next check in configuration Components to make sure the flowmeter/mag meter is connected to the Module that the flowmeter is Physically connected. Basically there are ...