Mag meter not measuring properly

Mag meter not measuring properly

Are power, signal lights lit? Check connection, cabling, plugs are seated securely.

Next check in configuration Components to make sure the flowmeter/mag meter is connected to the Module that the flowmeter is Physically connected.

Basically there are 2 reasons that the mag meter doesn't measure correctly if the above are correct:
1) If the actual is consistently different than what the Mixmate says, adjust the calibration:
      New Calibration = Mixmate/Actual*Old Calibration
      For example, Mixmate is showing 100 gallons, but your sprayer tank has 200 gallons and the current calibration is 24.
      100/200 x 24 = 12, so the new calibration would be 12
2) If the actual is sporadically different than what the Mixmate says - This IS a grounding issue - You must figure out what is putting the stray voltage into the liquid. 

3" Arag Mag meter light information.
Green - Liquid Present, No Flow
Blue - Liquid Present, Flow
Purple - No Liquid Detected, Typically Air
Red - Count flashes for error
Flashing Blue/Green - System is not properly grounded with external world.

All other Arag Mag meters
Light toggles Dim/Bright with flow

Also, consider running firmware updates.