Mixmate Machine Errors
Quick Reference: Power Module Blink Codes
Quick Reference: Power Module Blink Codes Blinks Meaning Top Priority Action 1 Blink Critical Low Voltage Charge battery; check ground and fuse. 2 Blinks Master Watchdog Timeout Reboot; check CAN bus resistance 60 Ohms. 3 Blinks CAN Communication ...
Power Module Blink Code - 4 Blinks
Power Module Blink Code: 4 Blinks A 4-Blink Error is a safety shutdown caused by a "Lost Tablet" condition. It occurs when the machine is in the middle of an active operation but loses its connection to the Mixmate App. What does this mean? If you ...
Power Module Blink Code - 3 Blinks
Power Module Blink Code: 3 Blinks A 3-Blink Error is a communication fault shutdown. It occurs when a critical error happens on the CAN bus network while the machine is actively running an operation. What does this mean? If you see the LED on the ...
Power Module Blink Code - 2 Blinks
Power Module Blink Code: 2 Blinks A 2-Blink Error is a safety-driven emergency shutdown. It occurs when the "watchdog" timer in the Power Module expires because it hasn't heard from the brain of the system. What does this mean? If you see the LED on ...
Power Module Blink Code - 1 Blink
Power Module Blink Code: 1 Blink A 1-Blink Error on the Power Module is a critical hardware alert indicating that the system has experienced a severe power drop, causing it to shut down to protect the electronics. What does this mean? If you see the ...