Direct Drive Small Electric Motor Wiring ( Less than 22 Amps )
IF YOU WANT MANUAL OVERRIDE, YOU MUST WIRE THROUGH A SWITCH BOX. For small motors ( 22 amps or less ) WEG makes a low current coil motor contactor that can be directly driven from a Praxidyn module. Find on Automation Direct The part number for this ...
Productivity study
(see report in Attachments)
Brochure 2023
Informational Brochure
Winterizing your Mixmate
Terminators Required
Two (2) blue* Terminators are REQUIRED to be connected to your Mixmate CANBUS for your system to run properly. They should be placed as far apart from each other as possible. (opposite ends of the CANBUS) Pro Inductors systems have one installed ...
Jug Rinse Sensor Replacement
Load Cell Connector Replacement
Plumbing Recommendations
Standard Carrier Valve Plumbing: In the above picture, the main water tank is connected to the hose on the bottom right corner. The first thing the water flows through is the flowmeter. Then you can see that the rinse line tees off the main line and ...
Double Gear Stack Drawing
Fusion Drawing
Slow mix time with thicker chemical(s)
When using a highly viscous chemical, it is possible to add a pump at the tote, so it can push the product into the Mixmate and move things along quicker. Make sure that the overall flowrate stays below 30 gal/min as to not damage gear meter. Lastly, ...
Recommended Tablet Links
Below are links to the recommended tablets that are used by Praxidyn to test all the software with. We utilize the Samsung Tab Active line because they have proven to hold up well in the chemical mixing environment. Cellular provides the advantage to ...